222 • Program Mode Programming Sam4S 230, 3xx, 4xx, 52xx Electronic Cash Register AU
Program 900 - Group Status Programming
Group Programming includes two different parts - Group Status and Kitchen Printing Routing.
“Group Total is Added to the Total of All Groups on the Group Report?” is default to YES. However,
when a PLU is assigned to more than one group, this option has to be reviewed carefully to avoid
duplication in the Group Report figure.
Programming the Group Status and KP
1. Turn the control lock to the PGM-Mode.
Switch to P Mode by press MODE function key. (For ER-230)
2. To begin the program, enter 9 0 0, press the SUBTL key.
3. Enter the number of the group you wish to program; press the X/TIME key.
4. Enter an option digit from the table below, press the SUBTL key.
Address OPTION VALUE = SUM
N1
Group total is added to the total of all groups on the
Group report?
Yes = 0
No = 1
Send to kitchen printer?
Yes = 2
No = 0
N2
No Choice
0
1
2
4
KP PORT#: R (print a kitchen requisition)
KP PORT#: 1
KP PORT#: 2 (not available on ER-380)
N3
Print RED on KP?
Yes = 1
No = 0
ÚDefault values have been highlighted in bold print
5. To program additional groups, repeat from step 3, or press the CASH key to finalise the
program.
CASH
0 SUBTL0 9
X/TIME
N2 SBTL N1
N3