EB 8384-0 EN 55
Servicing
8 Servicing
The positioner was checked by SAMSON
before it left the factory.
− The product warranty becomes void if ser-
vice or repair work not described in these
instructions is performed without prior
agreement by SAMSON's After-sales Ser-
vice department.
− Only use original spare parts by
SAMSON, which comply with the original
specications.
The positioner does not require any mainte-
nance.
Filters
Therearelterswitha100µmmeshsizein
the pneumatic connections for supply and
output which can be removed and cleaned,
if required.
Supply air pressure reducing stations
The maintenance instructions of any up-
stream supply air pressure reducing stations
must be observed.
8.1 Preparation for return ship-
ment
Defective positioners can be returned to
SAMSON for repair.
Proceed as follows to return devices to
SAMSON:
1. Put the control valve out of operation.
See associated valve documentation.
2. Removethepositioner(seesection10).
3. Send the positioner to your nearest
SAMSON subsidiary. SAMSON
subsidiaries are listed on our website at
uwww.samson.de>Contact.
9 Malfunctions
Î Troubleshooting(seeTable10)
Table10: Troubleshooting
Description of
fault Measures
Actuator moves
too slowly.
Î Check the supply
pressure.
Î Check the cross-section of
the piping and screw
ttings.
Î Checktheconguration
of the mounting parts.
Actuator moves
in the wrong
direction.
Î Check piping.
Î Checktheconguration
of the mounting parts.
Air leaks from
the positioner.
Î Check the seals in the
connecting plate.
Contact SAMSON's After-sales Service de-
partment for malfunctions not listed in the ta-
ble.
Note