3-24 Samsung Electronics
No Parts Procedure Remark
3 assy control out 1) lossen fixing 1 screw from cover -control
2) detach several connections from assy con-
trol out, take out assy control out.
4 Heat exchanger 1) Release the refrigerant at first
2) Looosen fixing screw on both side.
3) disaessembly the pipes in both inlet and
outlet with welding torch.
4) detach the heat exchanger.