EasyManua.ls Logo

Samsung AC052FBNDEH - Page 85

Samsung AC052FBNDEH
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-40 Samsung Electronics
4-4-10 DC_link voltage sensor error
1.Checklist :
1) Is the input voltage of outdoor terminal block is normal?
2) Is the reactor wire connected?
3) Is the DC_link capacitor(PF2:CE101,CE102,CE103,PF3:CE001,CE002,CE003,CE004)) assembled in accordance the specification?
(Outdoor PBA)
4) Is the DC_link resistor(PF2:R104,R106,R107,R108,PF3:R004,R005,R006,R007) value is normal? (Outdoor PBA)
2. Troubleshooting procedure
Connect the reactor wire
No
Is the connected of reactor wire?
(PBA-Reactor)
Is the DC_link voltage (CE101 or CE001) is
normal in operation mode?
Normal range(280Vdc~320Vdc)
Check the power input
No
No
No
No
Exchange the Outdoor PBA
Exchange the Outdoor PBA
Is the DC_link sensing voltage(R104 or R004) is normal in
operation mode?
Normal range (0.2Vdc~2.8Vdc)
Is the reactor insulation damaged?
Exchange the Reactor
Restart after power off.