Make sure that the line set is longer than is needed to
reach from the indoor to the outdoor unit, to allow for
bends and final connections. For more on pipe lengths, see
Step 1-1 Viewing the typical installation on page 6.
If not using a premanufactured line set:
Only use insulated seamless refrigeration-grade
copper pipe (Cu DHP-type according to ISO1337),
degreased and deoxidized, suitable for operating
pressures of at least 609 psig (4200 kPa) and for a
burst pressure of at least 3002 psig (20700 kPa).
Do not use sanitary-type copper pipe under any
circumstances.
Use standard cables.
Cable Terminal Wire Specification
Power cable L1, L2, ground
16AWG
(for **09*******,
**12*******,
**18TSFY***
12AWG
(for **18TSFA***,
**24*******)
Communication
cable
F1, F2
18AWG Standard
shield cable
NOTE
This manual does not include instructions for extending
cables. If you need to extend the cables, follow local codes.
Tools
Make sure you have the required tools available.
Safety tools
Service disconnect lock and tag
Circuit breaker lock and tag
Safety glasses
Cut-proof gloves
Hearing protection
Hard hat, for use in appropriate areas
Safety vest, for visibility as required
General tools
36-inch spirit level
8-inch to 9-inch torpedo level
Cordless drill
#2 Phillips-bit driver for cordless drill
Phillips screw driver
Slotted screw driver
Corded hammer drill, for masonry anchors if used
Masonry drill bit, for masonry anchors if used
Compact bandsaw, for cutting all thread and/or unistrut
channel as required
Stud finder, for stud-wall construction as required
2-5-inch hole saw, standard, or diamond core for
concrete or cinder block construction
Metric hex-key set
Razor knife
25-ft tape measure
Electrical tools
Clamp-on multimeter, for measuring volt AC,
resistance, and amperage
Non-contact thermometer (may be incorporated into
multimeter)
Wire strippers
Wire connector crimping tool
Cutting pliers
Piping tools
Flaring tool
Deburring tool
Piping bender, spring type
Tubing cutter, imp style
Tubing cutter, standard style
Open-end torque wrench (ft.-lbs.)
Crescent wrench
Refrigeration tools
Manifold set for R-410A
5/16-inch to ¼-inch flare adapter
Shrader core removal tool
2-stage vacuum pump with oil
Electronic refrigerant scale (lbs/oz), if additional
refrigerant is required due to line length
Recovery machine with tank, if required
Micron vacuum gauge
¼-inch vacuum gauge hose tee
Nitrogen regulator
Nitrogen cylinder, charged