4. Combination Table4. Combination Table
4-1 AJ040TXJ2KG/EU
COOLING
Outdoor unit A B
Cooling
Capacity
Capacity
Power
Consumption
Current
Efc. NOM.
Cooling.
At 35℃/27℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SEER
Qce
W W W A
A B MIN STD MAX MIN STD MAX MIN STD MAX EER Class kWh
AJ040TXJ2KG 2 Unit
7 7 2000 2000 1300 4000 4700 300 900 1250 1.7 4.1 5.7
4.44 A+++
8.54 164
7 9 1780 2220 1300 4000 4700 350 920 1270 1.9 4.2 5.8
4.35 A+++
8.51 165
7 12 1450 2550 1300 4000 4700 350 930 1280 1.9 4.3 5.9
4.3 A+++
8.51 165
9 9 2000 2000 1300 4000 4700 350 940 1290 1.9 4.3 5.9
4.26 A+++
8.51 165
9 12 1670 2330 1300 4000 4700 350 950 1300 1.9 4.3 5.9
4.21 A+++
8.51 165
HEATING
Outdoor unit A B
Heating
Capacity
Capacity
Power
Consumption
Current
Efc. NOM.
Heating.
At 7℃/20℃
SEASONAL
EFFICIENCY
(ACCORDING
EN14825)
SCOP
P
design
Qhe
W W W A
A B MIN STD MAX MIN STD MAX MIN STD MAX COP Class kW kWh
AJ040TXJ2KG 2 Unit
7 7 2100 2100 1000 4200 4700 280 900 1180 1.4 4.1 5.4
4.67 A++
4.64 3.05
922
7 9 1840 2360 1000 4200 4700 280 920 1190 1.4 4.2 5.4
4.57 A++
4.61 3.05
927
7 12 1550 2650 1000 4200 4700 280 930 1200 1.4 4.3 5.5
4.52 A++
4.61 3.05
927
9 9 2100 2100 1000 4200 4700 280 940 1210 1.4 4.3 5.5
4.47 A++
4.61 3.05
927
9 12 1800 2400 1000 4200 4700 280 950 1220 1.4 4.3 5.6
4.42 A++
4.61 3.05
927
NOTE
1
EER and COP declared only for the purpose of tax deductions in force at the time of the creation of this catalog.
2
The above is the value for connecting with the following indoor units.
- Wind Free(PRM) : AR07TXCAAWK, AR09TXCAAWK, AR12TXCAAWK
3
You can not connect a single unit.
4
Power consumption include indoor unit power.