EasyManua.ls Logo

Samsung CLP-31 Series - Page 52

Samsung CLP-31 Series
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disassembly and Reassembly
3-9
Samsung Electronics
3.4.2 ITB
3.4.3 Fuser
1. Unplug the one connector from OPE PBA and
pull out the ITB unit in the direction of bottom.
1. Remove the Right cover. And remove the 2
connector as shown below.
Caution - The fuser is very hot. So turn the printer
off and wait until the printer to cool before
replacing it.
2. Remove the 4 screw, and move the shaft as
shown below. And remove the Fuser unit.

Related product manuals