Alignment & Troubleshooting
Service Manual
4-38
Samsung Electronics
● Code
01-017
● Error message
Output bin Full
Output bin Full.
Remove printed paper
● Symptom
When the tray limit is reached, the out-bin full sensor is on for 600ms.
● Possible Cause
1. Check the Out-Bin Full Sensor.
2. Check if the UI message is changed by the Out-Bin Full Sensor operation.
3. Check the Out-Bin Full Sensor Harness and Connector.
● Troubleshooting method
1. Check the BIN_FULL_SENSOR (picture’1’ below) by pushing the trigger (picture’2’ below) beneath the SCAN_
ASSY.
Check if the UI message is changed by the Out-Bin Full Sensor operation
2. Check if the Harness is defective.
Check if the connector is connected properly.
3. Replace the Main PBA or the Scan_Joint PBA or the Panel PBA.
4. Enter the EDC mode and follow the below sequence after the repair is done.
( EDC Mode ˧ Test Routines ˧ 101-Clutch ˧ 0190-OutBin Full ˧ Start ˧ Status check ˧ Stop )