Code
NVM Description
(GUI)
Default
Max
/ Min
Function Description
102-000 Top Registration Tray1
Simplex
3 6/0 * You can adjust the Top Margin of simplex copy image for each
tray.
* The input value is reflected to the real image and it is equal to
mm.
* In case, the value is more than 3 :
Simplex copy top margin lengthen.
For example, if the value is 6, top margin lengthen 3 mm.
* In case, the value is less than 3 :
Simplex copy top margin shorten.
For example, if the value is 0, top margin shorten 3 mm.
102-010 Top Registration Tray2
Simplex
3 6/0
102-020 Top Registration Tray3
Simplex
3 6/0
102-040 Top Registration Bypass
Simplex
3 6/0
102-100 Top Registration Tray1
Dup_long (2nd side)
3 6/0 * You can adjust the Top Margin of duplex image of duplex copy
for each tray.
* The input value is reflected to the real image and it is same with
mm size.
* In case, the value is more than 3 :
Top Margin of duplex image of duplex copy lengthen.
For example, if the value is 6, top margin lengthen 3 mm.
* In case, the value is less than 3 :
Top Margin of duplex image of duplex copy shorten.
For example, if the value is 0, top margin shorten 3 mm.
102-110 Top Registration Tray2
Dup_long (2nd side)
3 6/0
102-120 Top Registration Tray3
Dup_long (2nd side)
3 6/0
102-140 Top Registration Bypass
Dup_long (2nd side)
3 6/0
102-200 Top Registration Tray1
Duplex (1st side)
3 6/0 * You can adjust the Top Margin of simplex image of duplex copy
for each tray.
* The input value is reflected to the real image and it is same with
mm size.
* In case, the value is more than 3 :
Simplex image top margin of duplex copy lengthen.
For example, if the value is 6, top margin lengthen 3 mm.
* In case, the value is less than 3 :
Simplex image top margin of duplex copy shorten.
For example, if the value is 0, top margin shorten 3 mm.
102-210 Top Registration Tray2
Duplex (1st side)
3 6/0
102-220 Top Registration Tray3
Duplex (1st side)
3 6/0
102-240 Top Registration Bypass
Duplex (1st side)
3 6/0
103-000 Pick Up Start Time 30 1000/0 * Pick up start time value
* You can read the value only.
103-010 Regi Off Time 92 500/0 * Regi Off Time value
* You can read the value only.
103-021 Option Clutch On Time 8 100/0 * Option clutch on time value
* You can read the value only.
104-000 Pick up roller Life Page
Counter
0 100000
/0
* Tray1 Pick up roller Page Counter value
* When replacing a svc part, you can change the count to 0.
104-030 T2 Pick-Up Roller Life
Page Counter
0 100000
/0
* Tray2 Pick up roller Page Counter value
* When replacing a svc part, you can change the count to 0.
104-040 T3 Pick-Up Roller Life
Page Counter
0 100000
/0
* Tray3 Pick up roller Page Counter value
* When replacing a svc part, you can change the count to 0.