►ErrorCode
S7–2110
►Errormessage
FuserFailure:#S7-2110.Turnoffthenon
►Symptom
Machinemakesrelayoffbecauseofabnormalheatercontrol.
►Troubleshootingmethod
1)Turnthemachineoff.Re-installthefuserunit,thenturnthemachineon.
(Referto3.2.4Fuserunit.)
2)Iftheproblempersists,turnthemachineoff.
3)Replacethefuserdriveboard(110V:JC44-00210A,220V:JC44-00211A)
4)Iftheproblempersists,replacethemainboard(JC92–02516A)
5)Iftheproblempersists,