Check the thermostat assembly status.
Check the harness/connector assembly status.
CAUTION
If the connector is not connected properly, overheatin
Check the assembly position, connection status.
After the fuser repair, check the following.
- The fuser unit weighs about 6 kg. Be careful not to d
- When installing fuser unit, hold the both side handle
- When installing fuser unit, do not apply force.
- Check if the both handles are locked properly.
- Fix 2 screws.
Service Manual
CLX-9250/9350 series
-
t Procedures
- Check if the thermostat is fixed properly.
- Check if both harness are connected properly.
If Thermostat or harness connection is not stable,
overheating/fire can occur because the overheat-
protective function can not be performed properly.
- Check if the NC thermistors are fixed properly.
- Check if the NC thermistor connectors are
connected properly.
CAUTION
If the NC thermistor connector is not connected
properly, overheating/fire can occur.