This report lists last 10 Auto Color Registration resul
If there is color registration problem , and execution
• Information > Print Reports > Auto Color R
4.3.6.1. Auto Color Registration Resu
problem, service engineers can print out this report
Result Meaning
0Success
100 Sensor LED calibration
200 Pattern storage failure i
301 Out of normal range in r
302 Out of normal range in f
304 Out of normal range in
ch)
316 Number of sensed patt
e.g.) 323
Multiple errors. For exa
480 Corrected value exceed
able
This report shows history of execution of TRC contr
changes in supplies resulting from long-time use an
report is to check if TRC control works normally.
• Information > Print Reports > TRC Control
4.3.6.2. TRC Control History
• If TRC control performs normally, “Pass” count m
• If “Fail” count is not zero, there is a cell that contai
“Loc(L,C,R)” column .
• If a value of certain color at “Er” column is non-ze
• If “LED” value is lager than 1600, it indicates that
working normally, and it has to be checked as well.
Service Manual
CLX-9250/9350 series
4
f Auto Color Registration does not solve the
nd check “Succeeded or Failed for ACR” field.
rn is lager than normal number (check ITB scrat
rn is smaller than normal number
ple 301, 302, 304, 316 error occur at the same t
m of last two digit appears as result
the limit of correction
3-2
l. TRC control preserves color consistency against
environmental change. The purpose of the history
st be non-zero value and “Fail” count must be zero.
ns non-zero value at “Er(Y,M,C,K)” column and/or
o, the image density sensor needs to be checked.
hutter that cleans the image density sensor is not
SAMSUNG ELECTRONICS