Purpose To correct image position and
function is used when a result
• Image Position - Si
• Magnification - Ver
2. Select one item and press
3. Change the adjustment val
4. Image Position (ⓐ, ⓑ) : If
press “+”. Otherwise, pres
“-”. Otherwise, press “+”.
6. Press the “OK” button to a
Example
Cases
ⓐ = 11.0 mm
* Note that value of magnificati
ⓑ = 9.0 mm
ⓒ = 191.7 mm
ⓒ = 188.1 mm
size, 420mm ((190mm + 10m
Verification 1. Scan the Scanner A/S Cha
from the scan glass.
2. To check the image positi
the chart to the copy.
3. To check the magnification
copy .
Specification
ⓐ,ⓑ : 10 , ± 1.5mm
ⓒ : 190 , ± 1.5mm
Image Position Unit: mm, Scal
Magnification Unit: %, Scale: 0.
Reference Figure 5-3
Service Manual
CLX-9250/9350 series
4-
agnification of scanned images manually. This
f automatic adjustment does not satisfy the
e table There are three items to choose
he current value is smaller than the specification,
urrent value is smaller than the specification
ply the new value to the system.
Leading
Edge
Side
Edge
Vertical Direction
Adjustment
-10
on adjustment needs to be calculated based on A3
+10
+0.8% (-3.4mm)
-0.4% (near +1.8mm)
*2)*2) if the used Scanner A/S Chart is A4 size.
rt and send it to a PC. Scanning must be occur
n, compare the position of scale marks (ⓐ,ⓑ) of
compare the length of line ⓒ of the chart to the
: 0.1, Min/Max: -6/+6
1(0.42mm), Min/Max: 99/101
SAMSUNG ELECTRONICS