● Code :
A1-1113
● Error message :
ctuator Motor Failu
7.2.2 Error Code Details
A1-1213
ctuator Motor Failu
● Symptom / Cause :
Fuser motor does not operate.
Fuser motor is operating but is recognized as stop sta
● Troubleshooting method :
1. Turn the machine off. Check if there is any foreign
2. Remove the fuser unit and reinstall it.
3. Turn the machine on. Is the problem solved?
If not, go to the next.
4. Turn the machine off.
Open the engine/video shield door.
Check if the fuser/exit motor connector is connecte
If the problem persists, replace the fuser/exit drive
Fuser/Exit drive
motor
5. If the motor operates normally, replace the fuser un
● Replacement part
- JC31-00123B (MOTOR BLDC)
- JC91-00931A (FUSER : 220V)
Service Manual
CLX-9250/9350 series
7-
- JC91-00930A (FUSER : 110V)
hooting
re #A1-1113: Please open/close door.
re #A1-1213: Please open/close door.
atter around the fuser unit.
otor. (Refer to 3.11.2 of the chapter 3)