● Code :
A1-1613
● Error message :
ctuator Motor Failu
● Symptom / Cause :
ITB motor does not operate.
ITB motor is operating but is recognized as stop statu
● Troubleshooting method :
1. Turn the machine off. Check if there is any foreign
2. Remove the ITB unit and reinstall it.
3. Turn the machine on. Is the problem solved?
4. Turn the machine off.
Open the engine/video shield door.
Check if the ITB BLDC motor connector is connect
If the problem persists, replace the ITB BLDC mot
5. Replace the motor and controller. If the motor oper
● Replacement part
- JC31-00123A (MOTOR BLDC)
- JC96-05689A : CARTRIDGE-TRANSFER ITB
Service Manual
CLX-9250/9350 series
7-
hooting
re #A1-1613: Please open/close door.
atter around the ITB unit.
r. (Refer to 3.8.2 of the chapter 3)
tes normally, replace the ITB unit.
SAMSUNG ELECTRONICS