● Code :
A1-2211
● Error message
● Symptom / Cause :
1. Yellow OPC motor is broken.
2. The relative connector is disconnected.
3. Deve joint board and main board are defective.
4. Even it was ready, it does not working.
5. After starting, it is not reached at ready state.
● Troubleshooting method :
1. Enter the diagnostic mode. Select the test routine.
Execute the yellow OPC BLDC motor test. If the m
2. If the problem persists, remove the rear cover.
3. Open the Main board plate.
4. Remove the yellow OPC BLDC motor and one of t
Install the removed yellow OPC BLDC motor to O
Execute the yellow OPC BLDC motor test on diag
5. If the motor doesn’t work, replace the yellow OPC
MCK
6. If the motor works, check the connection
7. Replace the Deve joint board or engine board.
● Replacement part
- JC31-00123A (MOTOR BLDC)
- JC92-02152A (DEVE-JOINT)
- JC92-02129A : PBA-ENGINE (CLX-9350ND)
Service Manual
CLX-9250/9350 series
7-
re #A1-2211: Please open/close door.
tor works, check the connection.