2.6.4 Temperature control
When the main switch turns on, the CPU turns on the
detect the standby temperature Then the CPU raises
Thermistor1
NC Sensor1
NC Sensor2
Thermo
Overheat Protection
The CPU cuts power to the fusing lamp in the followin
• The heating roller temperature detected by the NC s
• The heating roller temperature detected by the ther
The following components are destroyed when thermi
• Two thermostats for the heating roller get into line wi
• If one of the thermostat temperatures becomes high
lamp. If the other thermostat temperature becomes
the fusing lamp.
Service Manual
CLX-9250/9350 series
2-
escription
fusing lamp. The lamp stays on until the NC sensors
s the temperature up to the printing temperature
.
Lamp 1(700W) :
Center heating
Thermistor2
Lamp 2(600W) :
Side heating
nsors becomes higher than 198℃.
istors becomes higher than 210℃.
tor overheat protection fails:
th the common ground line of the fusing lamp.
r than 170°C, it opens and cuts power to the fusing
igher than 170°C, it also opens and cuts power to
SAMSUNG ELECTRONICS