English-35
OTHERS06
PROBLEM SOLUTION
Fan speed
adjustment is not
working.
• CheckifyouhaveselectedAuto/Dry/Fast/ mode.In
thesemode,fanspeedissettoAutoandyoucannotadjustthe
fanspeed.
Remote controller is
not working.
• Checkifyourbatteriesaredepleted.
• Makesurenothingisblockingyourremotecontrollersensor.
• Checkthattherearestronglightingapparatusneartheair
conditioner.Stronglightwhichcomesfromuorescentbulbsor
neonsignsmayinterrupttheelectricwaves.
Timer function does
not set.
• CheckifyoupresstheSet/Cancelbuttonontheremote
controllerafteryouhavesetthetime.
The indicator
is blinking
continuously.
• PressthePower buttonordisconnectthepowerplug/switch
otheauxiliarypowerswitch.
Iftheindicatorisstillblinking,contacttheservicecenter.
Odors permeate in
the room during
operation.
• Checkiftheapplianceisrunninginasmokyarea.Ventilatethe
roomoroperatetheairconditionerinFanmodefor1~2hours.
(Wedonotusesmellycomponentsintheairconditioner.)
• ChecktheDrainshavebeenclearedRegularMaintenance.
Error is indicated. • Whenanindoorunitindicatorblinks,contactthenearestservice
center.Pleaseensuretheerrorcodeispassedontotheservice
centerwhenbookingtheservicecall.
Noise is generated. • Dependingonthestatusoftheairconditionerusage,noisecan
beheardwhenrefrigerantowmovementchanges.Itisnormal.
Smoke is generated
from the outdoor
unit.
• Ifmaynotbearebutitcanbeasteamgeneratedbythedefrost
operationfromoutdoorheatexchangerduringHeatmodein
winter.
Water is dropping
from the outdoor unit
piping connection.
• Watermaybegeneratedbecauseofthetemperaturedierence.
Itisnormal.
Indoor unit display
indicates “
, ,
"
• Thisisnotadefect.IftheairconditionerreceivesaDemand
Responsesignalfromthepowersupplyutility,thenthe
compressorandfanswillbeoperatedaccordingtoDRM
mode(DRM1,2,3).Theindoorunitdisplaywillindicate
" , , ".
seepage15formoredetailsaboutDRMmode.
A3050 Australia_IB&IM_DB68-05206A_EN.indd 35 2014/12/31 15:58:10