1-2. Servicing Precautions
Warning
An electrolytic capacitor installed with the wrong polarity might explode.
Caution
Before servicing units covered by this service manual, read and follow the Safety Precautions section of
this manual.
Note
If unforeseen circumstances create conflict between the following servicing precautions and any of the
safety precautions, always follow the safety precautions.
1. Servicing precautions are printed on the cabinet. Follow them.
2. Always unplug the unit’s AC power cord from the AC power source before attempting to: (a) Remove or reinstall any
component or assembly, (b) Disconnect an electrical plug or connector, (c) Connect a test component in parallel with an
electrolytic capacitor.
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used. The
internal wiring may be clamped to prevent contact with thermally hot components. Reinstall all such elements to their original
position.
4. After servicing, always check that the screws, components and wiring have been correctly reinstalled.
Make sure that the portion around the serviced part has not been damaged.
5.
Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels, input
terminals and earphone jacks).
6. Insulation Checking Procedure: Disconnect the power cord from the AC source. Connect an insulation resistance meter
(500V) to the blades of the AC plug.
7. The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be greater
than 1 megohm.
8. Never defeat any of the B+ voltage interlocks. Do not apply AC power to the unit (or any of its assemblies) unless all solid-
state heat sinks are correctly installed.
9. Always connect a test instrument’s ground lead to the instrument chassis ground before connecting the positive lead; always
remove the instrument’s ground lead last.