EasyManua.ls Logo

Samsung Max Heat 2.0 - Page 37

Samsung Max Heat 2.0
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
5. Electrical Wiring Diagram
Quantum 2.0 : RXS24YBT (AR24TSFYBWKXCV)
Max Heat 2.0 : RXS18ACT (AR18TSFACWKXCV), RXS24ACT (AR24TSFACWKXCV)
Wind-Free™ 2.0 : RXS18ABT (AR18TSFABWKXCV), RXS24ABT (AR24TSFABWKXCV)
DRED
Printed circuit board(DRED
PCB)
DIS-TH
Thermistor
(Discharge Temp._200Kohm)
EEV-C
Electronic expansion
valve C
REACTOR REACTOR OUT-TH
Thermistor
(AmbientTemp._10Kohm)
EEV-A
Electronic expansion
valve A
EEPROM
Printed circuit
board(EEPROM PCB)
COND-TH
Thermistor
(Cond Out Temp._10Kohm)
EEV-B
Electronic expansion
valve B
COMP COMPRESSOR BLDC Motor(BLDC FAN Motor) HIGH PRESSURE PRESSURE SWITCH
HEATER
Printed circuit
board(HEATER PCB)
4-WAY VALVE 4WAY VALVE
NOTE
This wiring diagram applies only to the outdoor unit.
Colors BLK : black, BRN : brown, SKY-BLU : sky-blue, GRN/YEL : green/yellow, RED : red, YEL : yellow,
ORG : orange, BLU : blue, WHT:white
Protective earth(screw)
Outdoor units