4.Troubleshooting
CodeDisplayMeaning
102-0531T5LevelSensor1Detectswhenthestackheightoftray5LevelSensor1
102-0532T5LevelSensor2Detectswhenthestackheightoftray5LevelSensor2
102-0533T5InstallSensor1DetectwhenTrayT5installsensor1
102-0534T5InstallSensor2DetectwhenTrayT5installsensor2
102-0730T3KnockUpHomeSensorDetectwhenTrayT3knockuphomesensor.
102-0731T3ShiftTrayPaperEmptySensorDetectwhenpaperisinT3ShtTray
102-0732T3ShiftTrayLevelSensor1DetectswhenthestackheightofT3ShiftTraylevel
sensor1
102-0733T3ShiftTrayLevelSensor2DetectswhenthestackheightofT3ShiftTraylevel
sensor2
102-0734T3ShtPlateHomeSensorDetectwhenT3ShtPlatehomesensor
102-0735T3ShtPlateEndSensorDetectwhenT3ShtPlateendsensor
102-0736T3GateSolenoidHomeSensorDetectwhenT3GateSolenoidhomesensor
104-0000WasteInstallSensorDetectifWasteisinstalled.
105-0030BlackMHVBiasBlackMHVbiasvoltageonatnormaldrivelevel
106-0030BlackDevBiasBlackDevbiasvoltageonatnormaldrivelevel
106-0031BlackDevACBiasBlackDevbiasACvoltageonatnormaldrivelevel
106-0200HVPSInstalledDetectHVPSUnit
107-0033THV(-)BiasTHVminusbiasvoltageonatnormaldrivelevel
107-0034THVCCBiasTHVconstantcurrentplusbiasvoltage
107-0035THVCVBiasTHVconstantvoltageplusbiasvoltage
107-0165KEraserOnKEraserLampOn/Off
107-0169KEraserDetectDetectKeraserstatus
109-0000FuserTemperatureADetectswhatthetemperatureAisonfuser.
109-0010FuserTemperatureBDetectswhatthetemperatureBisonfuser.
109-0012InnerTemperatureInnerTemperature
109-0013OuterTemperatureOuterTemperature
109-0014HuminityHuminity
109-0020FuserFanRunReadyDetectsifFuserFanMotorrunsatnormalspeed.
109-0021Exit2FanRunStart/StopExit2Fanrun
109-0022Exit2FanRunReadyDetectsifExit2Fanrunsatnormalspeed.
109-0023Exit3FanRunStart/StopExit3Fanrun
109-0024Exit3FanRunReadyDetectsifExit3Fanrunsatnormalspeed.
109-0030FuserMotorForwardFuserMotorForwardOn/Off
109-0034FuserMotorReadyDetectifFuserMotorrunsateachspeed
109-0040FuserFanRunFuserFanMotorOn/Off
109-0046ExitFanRunExitFanMotorOn/Off
109-0047ExitFanRunReadyDetectsifFuserFanrunsatnormalspeed.
109-0130FuserGapMotorFuserpresscontrolmotorOn/Off
109-0140FuserGapHomeSensorDetectifthefuserpressislocatedHomeposition.
109-0200DetectFuserRelayDetectFuserRelayStatus