4.Troubleshooting
4.5.5.2.FaxDiagnostics
FaxNVMRead/Write
Diagnostics>FaxDiagnosticsFaxNVMRead/Write
PurposeTochangeacongurationvalueforfaxrmware.
OperationProcedureWhenthemain“NVMRead/Write”windowdisplays,userscannavigatethroughthelistof
congurationvaluesthatdisplayalongwithdescription.
Userscanalsoinputacodetothetextboxtondacongurationvaluedirectly.
Afterselectingonevalue,pressing“Edit”buttonwillopenaninterfaceforuserinput.
VericationN/A
SpecicationN/A
ReferenceN/A
CodeNameDescriptionDefaultRange
20-200PauseDialTimePauseTime(value*1000ms)Country
Value
0~200
20-210DialPulseM/Bratio33/6640/60Country
Value
0=OPTION_DP_33
1=OPTION_DP_40
2=OPTION_DP_37
3=OPTION_DP_50
20-220AutoDialStartPauseTimePausetimebeforeauto-dialing(second)10~10
20-300RingOnTimeRingOnTime(ms)17090~800
20-310RingOffTimeRingOffTime(ms)56090~800
20-320RingDetectionFreqsetstheCallIndicationfrequencyrange
thatwillbedetectedbyLIU
11=12-80hz
2=16-55hz
3=20-55hz
4=22-55hz
20-330RingOnMaxTimeRingOnMaxTime(ms)51003000~12000
20-340RingOffMaxTimeRingOffMaxTime(ms)111009000~22000
20-400DTMFHigh-FreqLevelDTMFHigh-Freq.Level(dBm)Country
Value
0~15
20-410DTMFLow-FreqLevelDTMFLow-Freq.Level(dBm)Country
Value
0~15
20-420DTMFTimingDTMFdurationofon/offoutput(Ms)81=80/80
2=70/70
3=70/150
4=60/60
5=80/100
6=150/50
7=150/240
8=100/100
9=100/80
20-500DialModeSelectTone/PulseCountry
Value
0=OPTION_TONE_MODE
1=OPTION_PULSE_MODE