4.Troubleshooting
Diagnostics>Adjustment>ScanAreaAdjustment>ManualAdjustment
PurposeTocorrectimagepositionandmagnicationofscannedimagesmanually.
OperationProcedure
1)Chooseoneitemfromthetable.Therearethreeitemstochoose.
ImagePosition-LeadingEdge(Unit:mm,Scale:0.1,Min/Max:-6/+6)
ImagePosition-SideEdge(Unit:mm,Scale:0.1,Min/Max:-6/+6)
Magnication-V erticalDirection(Unit:%,Min/Max:98.5/101.5)
2)Selectoneitemandpressthe“Edit”button.
3)Changetheadjustmentvaluewitharrowbutton.
4)ImagePosition(a,b):Ifthecurrentvalueissmallerthanthespecication,press“+”.
Otherwise,press“-”.
5)Magnication(c):Ifthecurrentvalueissmallerthanthespecication,press“-”.Otherwise,
press“+”.
6)Pressthe“OK”buttontoapplythenewvaluetothesystem.
7)ScantheScannerA/SChartandsendittoaPC.Scanningmustbeoccurfromthescanglass.
8)Tochecktheimageposition,comparethepositionofscalemarks(a,b)ofthecharttothe
scannedimage.
9)Tocheckthemagnication,comparethelengthofline“c”ofthecharttothescannedimage.
NOTE
Specication
a,b:10,±1.5mm
c:190,±1.5mm
4-53Copyright©1995-2017SAMSUNG.Allrightsreserved.