4.Troubleshooting
ADFAdjustment
•Diagnostics>Adjustment>ADFAdjustment>AutomaticAdjustment
PurposeTocorrectimagepositionandmagnicationofscannedimagesviaDSDFautomatically.
OperationProcedure
1)LocatetheScannerA/SchartontheDSDFtray.
2)Press“OK”button.Automaticscanningwilloccur,andthesystemwillautomatically
calculatethepropervaluebasedonscanningresultofthechart.
3)Thenewvaluesettothesystem.
4)CopytheScannerA/SChart.ScanningmustbeoccurfromtheDSDF.
5)Tochecktheimageposition,comparethepositionofscalemarks(a,b)ofthecharttothe
copy.
6)Tocheckthemagnication,comparethelengthofline“c”ofthecharttothecopy.
NOTE
Specication
•a,b:10,±1.5mm
•c:190,±1.5mm
NOTE
AfterexecutingADFadjustment,theshadingtestmustbeexecuted.(Referto4.5.5.3.Scanner
Diagnostics.)
Copyright©1995-2017SAMSUNG.Allrightsreserved.4-54