4.Troubleshooting
•Diagnostics>Adjustment>ADFAdjustment>ManualAdjustment
PurposeTocorrectimagepositionandmagnicationofscannedimagesmanually.
OperationProcedure
NOTE
AfterexecutingADFadjustment,theshadingtestmustbeexecuted.(Referto4.5.5.3.Scanner
Diagnostics.)
1)Chooseoneitemfromthetable.Therearethreeitemstochoose.
•ImagePosition-LeadingEdge(Unit:mm,Scale:0.1,Min/Max:-6/+6)
•ImagePosition-SideEdge(Unit:mm,Scale:0.1,Min/Max:-6/+6)
•Magnication-V erticalDirection(Unit:%,,Min/Max:98.5/101.5)
2)Selectoneitemandpressthe“Edit”button.
3)Changetheadjustmentvaluewitharrowbutton.
4)ImagePosition(a,b):Ifthecurrentvalueissmallerthanthespecication,press“+”.
Otherwise,press“-”.
5)Magnication(c):Ifthecurrentvalueissmallerthanthespecication,press“-”.Otherwise,
press“+”.
NOTE
Specication
•a,b:10,±1.5mm
•c:190,±1.5mm
6)Pressthe“OK”buttontoapplythenewvaluetothesystem.
7)CopytheScannerA/SChart.ScanningmustbeoccurfromtheDSDF.
8)Tochecktheimageposition,comparethepositionofscalemarks(a,b)ofthecharttothe
copy.
9)Tocheckthemagnication,comparethelengthofline“c”ofthecharttothecopy.
10)If"AutoSkewCorrectionduringjob"boxischecked,skewedimageiscorrectedbydigitally
rotatingthescannedimages.
4-55Copyright©1995-2017SAMSUNG.Allrightsreserved.