4.Troubleshooting
►ErrorCode
A1–1111
A1–1113
►Errormessage
MotorFailure:#A1-1111.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1113.Turnoffthenon.Callforserviceiftheproblempersists.
►Symptom
Regi/MPmotordoesnotoperate./Regi/MPmotorisoperatingbutmachinerecognizesstatusas"Stopped".
►Troubleshootingmethod
NOTE
Toseethetroubleshootingvideoforthiserror,clickthroughtothelinkbelow.
•A1–1111:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A1-1111.html
•A1–1113:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A1-1113.html
1)Turnthemachineoffthenon.Iftheerrorpersists,checkthefollowing.
2)Openthesidecover.CheckifthereareanyforeignsubstancesorpaperaroundRegi./MPunit.
3)Removetherearcover.
4)Checktheconnectionbetweenthemotorandmainboard.
5)IftheconnectionisOK,enterSVCmode.Executethemotortest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
a)Ifthemotorisnotoperational,
i)Checkthemotorsignal(3.3V).Ifthesignalisabnormal,replacethemainboard.
ii)Checkthepower(24V).Ifthepowerisabnormal,checktheSMPSboard.IftheSMPSboardisdefective,
replaceit.
iii)Ifthemotorsignalandpowerisnormal,replacetheFeed/MPmotor.
b)Ifthemotorisoperational,replacethemainboard.
Copyright©1995-2017SAMSUNG.Allrightsreserved.4-72