4.Troubleshooting
►ErrorCode
A1–1211
A1–1213
►Errormessage
MotorFailure:#A1-1211.Turnoffthenon.Callforserviceiftheproblempersists.
MotorFailure:#A1-1213.Turnoffthenon.Callforserviceiftheproblempersists.
►Symptom
Fusermotordoesnotoperate./Fusermotorisoperationalbutmachinerecognizesstatusasstopped.
►Troubleshootingmethod
NOTE
Toseethetroubleshootingvideoforthiserror,clickthroughtothelinkbelow.
•A1–1211:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A1-1211.html
•A1–1213:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A1-1213.html
1)Turnthemachineoffthenon.Iftheerrorpersists,checkthefollowing.
2)Openthesidecover.Checkifthereareanyforeignsubstancesorpaperaroundfuserunit.
3)Removetherearcover.
4)Checktheconnectionbetweenthemotorandmainboard.
5)IftheconnectionisOK,enterSVCmode.Executethemotortest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
a)Ifthemotorisnotoperational,
i)Checkthemotorsignal(3.3V).Ifthesignalisabnormal,replacethemainboard.
ii)Checkthepower(24V).Ifthepowerisabnormal,checktheSMPSboard.IftheSMPSboardisdefective,
replaceit.
iii)Ifthemotorsignalandpowerisnormal,replacetheFuser/Exitmotor.
b)Ifthemotorisoperational,replacethemainboard.
4-73Copyright©1995-2017SAMSUNG.Allrightsreserved.