4.Troubleshooting
►ErrorCode
A3–3310/A3–3311/A3–3312
A3–3410/A3–3411/A3–3412
►Errormessage
SensorFailure:#A3-3310.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3410.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3411.Turnoffthenon.Callforserviceiftheproblempersists
SensorFailure:#A3-3412.Turnoffthenon.Callforserviceiftheproblempersists
►Symptom
Outertemperature/humiditysensorisdefective.
►Troubleshootingmethod
NOTE
Toseethetroubleshootingvideoforthiserror,clickthroughtothelinkbelow.
•A3–3310:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3310.html
•A3–3311:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3311.html
•A3–3312:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3312.html
•A3–3410:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3410.html
•A3–3411:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3411.html
•A3–3412:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_A3-3412.html
•A3–3310/A3–3311/A3–3312:Temperaturefunctionisabnormal.
•A3–3410/A3–3411/A3–3412:Humidityfunctionisabnormal.
1)Turnthemachineoffthenon.
2)Checktheconnectionbetweentheoutertempsensorandmainboard.IftheconnectionisOK,replacetheouter
tempsensor.
3)Ifthesensorisnormal,replacethemainboard.
Copyright©1995-2017SAMSUNG.Allrightsreserved.4-80