4.Troubleshooting
4.6.8.C6–xxxx(Fuseruniterror)
ErrorCodeErrorMessageTroubleshootingPage
C6-1120ReplacewithnewfuserunitP.4–88
C6-1310Fuserunitisnotinstalled.InstallitP.4–88
ErrorCode
C6–1120
Errormessage
Replacewithnewfuserunit
Symptom
Thelifeofthefuserunithasexpired.
Troubleshootingmethod
1)Turnthemachineoff.
2)Replacethefuserunit.
3)Turnthemachineon.
ErrorCode
C6–1310
Errormessage
Fuserunitisnotinstalled.Installit.
Symptom
Thefuserunitisnotinstalledorfuserunitconnectorisnotconnectedproperly.
Troubleshootingmethod
NOTE
Toseethetroubleshootingvideoforthiserror,clickthroughtothelinkbelow.
(http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_C6-1310.html)
1)Turnthemachineoffthenon.
2)Iftheproblempersists,turnthemachineoffagain.
3)Openthesidecover.Checkifthefuserunitisinstalled.Ifnot,installthefuserunit.
4)Ifthefuserunitisinstalled,removeit.
5)Checkifthefuserdrawconnectorisbrokenordefective.
6)Installthefuserunit.
7)Iftheproblempersists,replacethefuserunit.
CAUTION
Thetemperaturegetshighinthevicinityofthefuserunit.Whenreplacingit,youmaygetburned.Beforereplacing
it,makesurethatfuserunithascooled.
Copyright©1995-2017SAMSUNG.Allrightsreserved.4-88