4.Troubleshooting
ErrorCode
H1-1322
Errormessage
Tray3cassetteispulledout.Insertitproperly.
Symptom
Tray3ispulledoutortheautosizesensorconnectorisnotconnectedorbroken.
Troubleshootingmethod
1)Removeandinserttray3correctly.
2)Iftheproblempersists,removetray3andtray4.Lookinsidemachine.
3)Checkiftheautosizesensorcableisconnectedcorrectly.Unplugandreconnectit.
4)IftheconnectionisOK,replacetheautosizesensor(JC32-00013A).
5)Iftheproblempersists,replacetheDCFPBA(JC92-02738A).