4.Troubleshooting
ErrorCode
U2–1111/U2–1112/U2–1114
Errormessage
LSUFailure:#U2-111x.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
LSUmotordoesnotoperateoritoperatesabnormally.Motorreadysignalisabnormal.
Troubleshootingmethod
NOTE
Toseethetroubleshootingvideoforthiserror,clickthroughtothelinkbelow.
U2–1111:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_U2-1111.html
U2–1112:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_U2-1112.html
U2–1114:http://tsp.samsung.com/tsp_le/spds/samsungprinter/K7/Webview/EN_K7_U2-1114.html
CAUTION
BeforeunpluggingtheLSUharness,themachinemustbeturnedoffandpowercordmustberemoved.
1)Turnthemachineoffthenon.CheckfortheLSUmotoroperationsoundduringwarm-up.
2)Printademopagetocheckthatthemachineoperatesnormally.
3)Iftheproblempersists,checkthefollowing:
a)IftheLSUmotormakesasound,
i)EnterSVCmodetochecktheLSUmotorreadysignal.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
ii)Select“LSUMotor1RunReady”.
iii)Press‘Start’button.Checkthatthestatushaschangedto‘Executing->Low->High’.
iv)Ifthestatushasnotchanged,themotorreadysignalisabnormal.ReplacetheLSU.
b)IftheLSUmotordoesnotmakesasound,
i)Turnthemachineoffandopenthesidecover.UnplugandreconnecttheLSUcable.CheckthattheLSU
motormakeasoundafterturningthemachineon.
ii)Turnthemachineoffandremovetherearcover.UnplugandreconnecttheLSUcableonmainboard.
CheckthattheLSUmotormakeasoundafterturningthemachineon.
iii)IftheLSUcableisdefective,replaceit.CheckthattheLSUmotormakeasoundafterturningthe
machineon.
iv)Iftheproblempersists,replacetheLSU.