2.ProductSpecicationsandDescription
5)Thermostat
Thermostatscutoffthepowersupplytothehalogenlampbyopeningthecircuitwhenthefusingbeltbecomes
abnormallyhotasaresultofproblemssuchasNCsensormalfunction.Thesethermostatsareusedtopreventabnormal
operation.Whenthethermostatistriggered,itmustbereplaced(aswellastheotherdamagedpartsinthefuserunit).
2.6.2.FuserUnitdrive
Thefusermotor[A]drivesthepressureroller[B]throughthegeartrain.Thefusingbelt[C]pressurizedbythepressure
roller[B]isrotatedbydrivingit.
2-48Copyright©1995-2017SAMSUNG.Allrightsreserved.