EasyManua.ls Logo

Samsung MultiXpress K7 Series - Fuser Unit Temperature Control

Samsung MultiXpress K7 Series
519 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2.ProductSpecicationsandDescription
2.6.3.Fuserunittemperaturecontrol
Whenthemainswitchturnson,theCPUturnsonthefusinglamp.ThelampstaysonuntiltheNCsensorsdetectthestandby
temperature.ThentheCPUraisesthetemperatureuptotheprintingtemperature.
OverheatProtection
TheCPUcutspowertothefusinglampinthefollowingcases:
ThebelttemperaturedetectedbytheNCsensorskeepshigherthan220°Cfor20sec.
ThebelttemperaturedetectedbytheNCsensorskeepshigherthan230°Cfor3sec.
TherelayoffworkswhenbelttemperaturedetectedbytheNCsensorsishigherthan230°C
Thefollowingcomponentsareusedwhenthermistoroverheatprotectionfails:
Twothermostatsgetintolinewiththecommongroundwireofthefusinglamp.
Ifoneofthethermostattemperaturesbecomeshigherthan195°C,itopensandcutspowertothefusinglamp.Ifthe
otherthermostattemperaturebecomeshigherthan195°C,italsoopensandcutspowertothefusinglamp.
Copyright©1995-2017SAMSUNG.Allrightsreserved.2-49