EasyManua.ls Logo

Samsung MultiXpress M4370 Series - Fax Diagnostics

Samsung MultiXpress M4370 Series
423 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
4.5.5.2.FaxDiagnostics
FaxNVMRead/Write
Diagnostics>FaxDiagnosticsFaxNVMRead/Write
PurposeTochangeacongurationvalueforfaxrmware.
OperationProcedureWhenthemain“NVMRead/Write”windowdisplays,userscannavigatethroughthelistof
congurationvaluesthatdisplayalongwithdescription.
Userscanalsoinputacodetothetextboxtondacongurationvaluedirectly.
Afterselectingonevalue,pressing“Edit”buttonwillopenaninterfaceforuserinput.
VericationN/A
SpecicationN/A
ReferenceN/A
CodeNVMNameNVMDescriptionDefault
20-200PauseDialTimePauseTime(value*1000ms)Country
Value
20-210DialPulseM/Bratio33/6640/60Country
Value
20-220AutoDialStartPauseTimePausetimebeforeauto-dialing(second)1
20-300RingOnTimeRingOnTime(ms)170
20-310RingOffTimeRingOffTime(ms)560
20-320RingDetectionFreqsetstheCallIndicationfrequencyrangethat
willbedetectedbyLIU
1
20-330RingOnMaxTimeRingOnMaxTime(ms)5100
20-340RingOffMaxTimeRingOffMaxTime(ms)11100
20-400DTMFHigh-FreqLevelDTMFHigh-Freq.Level(dBm)Country
Value
20-410DTMFLow-FreqLevelDTMFLow-Freq.Level(dBm)Country
Value
20-420DTMFTimingDTMFdurationofon/offoutput(Ms)8
20-500DialModeSelectTone/PulseCountry
Value
20-520ErrorRateAdjustErrorRate(Off/5%/10%/20%)2
20-530DialToneDetectdetectdialtonepriortosendingCountry
Value
20-540LoopCurrentDetectdetectifloopcurrentispresentpriortosendingCountry
Value
20-550BusySignalDetectdetectbusysignaltoallowredialsCountry
Value
20-560TCFDurationAdjustTCFduration(ms)1500
20-800ModemSpeedSelectModemStartSpeed24
20-810FaxTransmissionLevelAdjustFaxTransmissionLevel(dBm)Country
Value
20-830AutoDialTimeoutAdjustAutoDialTimeout(second)Country
Value
4-52Copyright©1995-2016SAMSUNG.Allrightsreserved.