4.Troubleshooting
4.6.7.U1-xxxxtype(Fuser)errorcode
ErrorCode
U1–2115
Errormessage
FuserUnitFailure:#U1-2115.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
Thepressurecontrolunit(Camunit)ofthefuserisabnormal.
Troubleshootingmethod
CAUTION
ThetemperaturegetshotaroundtheFuserUnit.Topreventburns,makesuretheFuserUnitareaiscoolbefore
performingthisprocedure.
1)Turnthemachineoffthenon.
2)Turnthemachineoff.Re-installthefuserunit.Thenturnthemachineon.
3)Iftheproblempersists,removetherearcover.Checkifthefuserconnectorisconnectedcorrectly.
4)IftheconnectionisOK,removethefuserunit.
5)Checkthepressurecontrolunitofthefuser.
6)Iftheproblempersists,replacethefuserunit.
7)Iftheproblempersists,replacethefuserpressuremotor.
8)Iftheproblempersists,replacethemainboard.