4.Troubleshooting
►ErrorCode
A1–1111
A1–1112
A1–1113
►Errormessage
MotorFailure:#A1-1111.Turnoffthenon.Callforserviceiftheproblempersists
MotorFailure:#A1-1112.Turnoffthenon.Callforserviceiftheproblempersists
MotorFailure:#A1-1113.Turnoffthenon.Callforserviceiftheproblempersists
►Symptom
Mainmotoroperationisabnormal.
►Troubleshootingmethod
•A1–1111:Mainmotorisstoppedbutmachinerecognizesitasoperational.
•A1–1112:Mainmotorisnotoperatedforprint-job.
•A1–1113:Mainmotorisoperatingbutmachinerecognizesstatusas"Stopped".
1)Turnthemachineoff.Checkifthereareanyforeignsubstancesorpaperaroundthepaperpath.
2)Removetherearcoverafterremoving6screws.
3)Checkifthemainmotorconnectorisconnectedcorrectly.
4)IftheconnectionisOK,turnthemachineon.EnterSVCmode.Selectthemainmotortest.
(Diagnostics>EngineDiagnostics>EngineTestRoutines)
Checkthemotoroperation.
a)Ifthemotorisnotoperational,
Copyright©1995-2016SAMSUNG.Allrightsreserved.4-83