4.Troubleshooting
►ErrorCode
A3–3210
A3–3211
A3–3212
►Errormessage
SensorFailure:#A3-3210.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3211.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3212.Turnoffthenon.Callforserviceiftheproblempersists.
►Symptom
Innertemperaturesensorisdefective.
►Troubleshootingmethod
•A3–3210:Innertemperaturesensorvalueisabnormal.
•A3–3211:Innertemperaturesensorisinshortstatus.
•A3–3212:Innertemperaturesensorisinopenstatus.
1)EnterSVCmode.Executesensortesttocheckthesensoroperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines>109-0012InnerTemperature)
2)Openthesidecover.Measuretheresistancevalueoftheconnectoratbothends.
•Ifthevaluesisnotin10KΩ±1%(@25℃),replacetheinnertemperaturesensor
3)Ifthesensorisnormal,replacethemainboard(JC92–02661A).
4-88Copyright©1995-2016SAMSUNG.Allrightsreserved.