4.Troubleshooting
4.5.5.2.FaxDiagnostics
FaxNVMRead/Write
•Diagnostics>FaxDiagnosticsFaxNVMRead/Write
PurposeTochangeacongurationvalueforfaxrmware.
OperationProcedureWhenthemain“NVMRead/Write”windowdisplays,userscannavigatethroughthelistof
congurationvaluesthatdisplayalongwithdescription.
Userscanalsoinputacodetothetextboxtondacongurationvaluedirectly.
Afterselectingonevalue,pressing“Edit”buttonwillopenaninterfaceforuserinput.
VericationN/A
SpecicationN/A
ReferenceN/A
CodeNVMNameNVMDescriptionDefault
20-200PauseDialTimePauseTime(value*1000ms)Country
Value
20-210DialPulseM/Bratio33/6640/60Country
Value
20-220AutoDialStartPauseTimePausetimebeforeauto-dialing(second)1
20-300RingOnTimeRingOnTime(ms)170
20-310RingOffTimeRingOffTime(ms)560
20-320RingDetectionFreqsetstheCallIndicationfrequencyrangethat
willbedetectedbyLIU
1
20-330RingOnMaxTimeRingOnMaxTime(ms)5100
20-340RingOffMaxTimeRingOffMaxTime(ms)11100
20-400DTMFHigh-FreqLevelDTMFHigh-Freq.Level(dBm)Country
Value
20-410DTMFLow-FreqLevelDTMFLow-Freq.Level(dBm)Country
Value
20-420DTMFTimingDTMFdurationofon/offoutput(Ms)8
20-500DialModeSelectTone/PulseCountry
Value
20-520ErrorRateAdjustErrorRate(Off/5%/10%/20%)2
20-530DialToneDetectdetectdialtonepriortosendingCountry
Value
20-540LoopCurrentDetectdetectifloopcurrentispresentpriortosendingCountry
Value
20-550BusySignalDetectdetectbusysignaltoallowredialsCountry
Value
20-560TCFDurationAdjustTCFduration(ms)1500
20-800ModemSpeedSelectModemStartSpeed24
20-810FaxTransmissionLevelAdjustFaxTransmissionLevel(dBm)Country
Value
20-830AutoDialTimeoutAdjustAutoDialTimeout(second)Country
Value
Copyright©1995-2013SAMSUNG.Allrightsreserved.4-51