4.Troubleshooting
ErrorCode
A3–3210
A3–3211
A3–3212
Errormessage
SensorFailure:#A3-3210.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3211.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3212.Turnoffthenon.Callforserviceiftheproblempersists.
Symptom
Innertemperaturesensorisdefective.
Troubleshootingmethod
A3–3210:Innertemperaturesensorvalueisabnormal.
A3–3211:Innertemperaturesensorisinshortstatus.
A3–3212:Innertemperaturesensorisinopenstatus.
1)EnterSVCmode.Executesensortesttocheckthesensoroperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines>109-0012InnerTemperature)
2)Openthesidecover.Measuretheresistancevalueoftheconnectoratbothends.
Ifthevaluesisnotin10KΩ±1%(@25),replacetheinnertemperaturesensor
3)Ifthesensorisnormal,replacethemainboard(JC92–02661A).
4-86Copyright©1995-2013SAMSUNG.Allrightsreserved.