4.Troubleshooting
ErrorCode
A3–3310
A3–3311
A3–3312
A3–3320
A3–3410
A3–3411
A3–3412
Errormessage
SensorFailure:#A3-3310.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists.
Theroomtemperatureisnotsuitableforthissetuse.Pleaseadjustroomtemperature
SensorFailure:#A3-3410.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3411.Turnoffthenon.Callforserviceiftheproblempersists.
SensorFailure:#A3-3412.Turnoffthenon.Callforserviceiftheproblempersists.
Symptom
Outertemperature/humiditysensorisdefective.
Troubleshootingmethod
A3–3310/A3–3311/A3–3312/A3–3320:Temperaturefunctionofthesensorisabnormal.
A3–3410/A3–3411/A3–3412:Humidityfunctionofthesensorisabnormal.
1)EnterSVCmode.Executesensortesttocheckitsoperation.
(Diagnostics>EngineDiagnostics>EngineTestRoutines>109-0013OuterTemperature)
2)Removetheleftcover.
Measuretheresistancevalueoftheconnectoratbothends.
Ifthevalueisnotin47.5KΩ~52.5KΩ(@25),replacetheoutertemperature/humiditysensor(JC32–00015A).
3)Iftheharnessandsensorarenormal,replacethemainboard(JC92–02661A).