4.Troubleshooting
ErrorCode
U1–2117
U1–212x
U1–213x
U1–23xx
Errormessage
FuserUnitFailure:#U1-21xx.Turnoffthenon.
FuserUnitFailure:#U1-23xx.Turnoffthenon.
Symptom
Thetemperaturecontroloffuserunitisabnormal.Thefusertemperaturehasdroppedbelowthenormalvalue.
Troubleshootingmethod
CAUTION
ThetemperaturegetshotaroundtheFuserUnit.Topreventburns,makesuretheFuserUnitareaiscoolbefore
performingthisprocedure.
1)Turnthemachineoffthenon.
2)Turnthemachineoff.Re-installthefuserunit.Thenturnthemachineon.
3)Iftheproblempersists,removethefuserunit.
4)Checkthefusercomponents.
Checkifthethermistorisassembledcorrectly.
Checkifthethermostatisconnected.
Checkifthecenterandsidelampsareinshortstatus.(Measuretheresistancevaluebetweenthecommon-center
andcommon-side.)
5)Ifthereareanydefectivepartsinstep5,replacethefuserunit.
6)Iftheproblempersists,replacethesepartsinregularsequence.
FuserDriveBoard
Mainboard
SMPSboard