2.ProductSpecicationsandDescription
2.5.3.ImagingUnit
Theimagingunitisnottheseparatedtypebutintegratedtype.Itisconsistsofthedrumunitanddeveloperunit.But
theycannotbereplacedseparately.
TheimagingunithastheCRUMthatstorestheinformationforcorrespondingthedrumunitanddeveloperunit.
TheOPCdrumdiameteris30mm(circumference:about94.2mm).
ThedevelopinggapbetweenaOPCdrumandthemagneticrollercannotbeadjusted.
2-34Copyright©1995-2013SAMSUNG.Allrightsreserved.