4.AlignmentandTroubleshooting
ErrorCode
H1-1230
Errormessage
Error:#H1-1230/InputSystemFailure:#H1-1230.Checktray2connection
Symptom
Communicationerrorhasoccurred.
Troubleshootingmethod
1)Turnthemachineoffthenon.
2)Iftheproblempersists,turnthemachineoff.
3)RemovetheSCFrightcover.(Referto3.3.23.1
)
4)CheckiftheinterfaceconnectorisconnectedtotheSCFmainboard.Iftheinterfaceconnectorisdefective,
replaceit.
5)Iftheproblempersists,replacetheSCFmainboard.(JC92-02636A)
4-53Copyright©1995-2013SAMSUNG.Allrightsreserved.