Samsung ProXpress M4030 Series - Error: #A3-3311; Sensor Failure: #A3-3311. Turn off then On. Call for Service if the Problem Persists; Error: #A3-3312; Sensor Failure: #A3-3312. Turn off then On. Call for Service if the Problem Persists; Not Proper Room Temp; the Room Temperature Is Not Suitable for this Set Use. Please Adjust Room Temperature

Samsung ProXpress M4030 Series
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
A3–3311
A3–3312
A3–3320
Errormessage
Error:#A3-3311/SensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists
Error:#A3-3312/SensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists
NotproperRoomTemp/Theroomtemperatureisnotsuitableforthissetuse.Pleaseadjustroomtemperature
Symptom
Outertemperaturesensorisdefective.
Troubleshootingmethod
1)Turnthemachineoffthenon.
2)Checkifthemachineisinstalledinproperenvironment.
3)Checktheharnessconnectionbetweenmainboardandtemperaturesensor.Reconnectthesensorharness.
4)Iftheproblempersists,replacethemainboard.
4-40Copyright©1995-2017SAMSUNG.Allrightsreserved.