Samsung ProXpress M4030 Series - Error #S7-2110; Fuser Unit Failure: #S7-2110. Turn off then On. Call for Service if the Problem Persists; Error: #S6-3234; Failed Connection to WPS. Try Again or Set up Other Wireless Connection; Error: #S6-3235; Wi-Fi Direct Is Not Ready. Turn off then On. Call for Service if the Problem Persists; Error: #S6-3236; Failed to Connect to Wi-Fi Direct. Turn off Your Mobile Device and Turn It

Samsung ProXpress M4030 Series
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.Troubleshooting
ErrorCode
S6-3234
Errormessage
Error:#S6-3234/FailedconnectiontoWPS.Tryagainorsetupotherwirelessconnection
Symptom
WPSconnectiontoAPisfailed.
Troubleshootingmethod
1)RetrytheconnectionwithWPSbutton.
ErrorCode
S6-3235
S6-3236
Errormessage
Error:#S6-3235/Wi-FiDirectisnotready.Turnoffthenon.Callforserviceiftheproblempersists
Error:#S6-3236/FailedtoconnecttoWi-FiDirect.Turnoffyourmobiledeviceandturniton
Symptom
Wi-FiDirectlibraryisinitialized.
Troubleshootingmethod
1)Turnthemachineoffthenon.
2)Changethewirelessnetworksettings.Retryit.
ErrorCode
S7–2110
Errormessage
Error#S7-2110/FuserUnitFailure:#S7-2110.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
Heatcontrolrelayoperationisabnormal.
Troubleshootingmethod
1)Turnthemachineoff.Re-installthefuserunit.Thenturnthemachineon.Istheerrormessageisdisappeared?
2)Iftheproblempersists,turnthemachineoffandremovethefuserunit.
a)Checkifthefuserconnectorisconnectedproperly.
b)Checkiftheinputvoltageisnormal.
c)Checkifthethermistoristwistedorcontaminated;andisincontactwiththeHeatRoller.
3)Afterconrmingcontinuityinthefuserconnectorandtheproblemstillexists;orderanSMPSandFuserUnit
andinstallasisnecessary.