4.Troubleshooting
ErrorCode
A3–3311/A3–3312
Errormessage
Error:#A3-3311/SensorFailure:#A3-3311.Turnoffthenon.Callforserviceiftheproblempersists
Error:#A3-3312/SensorFailure:#A3-3312.Turnoffthenon.Callforserviceiftheproblempersists
Symptom
Theoutertemperaturesensorisdefective.
Troubleshootingmethod
1)Turnthemachineoffthenon.Iftheerrorpersists,turnthemachineoffagain.
2)Enterthetechmode.Checkthetemperaturesensoroutput.
3)Ifthesensorisdefective,replaceit.
4)IfthetemperaturesensorisOK,replacethemainboard.
ErrorCode
A3–3320
Errormessage
NotproperRoomTemp/Theroomtemperatureisnotsuitableforthissetuse.Pleaseadjustroomtemperature
Symptom
Thevalueoftheoutertemperaturesensorisoutofnormalarea.
Troubleshootingmethod
1)Checkifthemachineisinstalledintheproperarea.
2)Ifthetemperaturesensorisdefective,replaceit.
4-50Copyright©1995-2017SAMSUNG.Allrightsreserved.