3-15
Samsung Electronics
CIRCUIT DESCRIPTION
Repair Manual
3-2-5-3 EDO DRAM read timing
Basically the Extended Data Out DRAM is similar to Fast Page Mode DRAM. For FPM, the data are valid only when the
nCAS is active while reading the internal data, however, it has a latch that the data will be
continuously outputted even after the nCAS is inactivated.
While configuring the software, you must set the timing register of SFR considering the clock speed and the DRAM spec.
5Mhz
MCLK
DRAMD
nWE
nOE
DRAMA
nCAS
nRAS
data 1
da
t
a0
row address
column
Trp
Trc Tcas
Tcas
addr
wait
wait
data
data
column
<EDO Read Timing Diagram>