Message Description Suggested solutions
Shake toner cartridge. The toner supply is low. Thoroughly roll the new cartridge ve
or six times to distribute the toner
evenly inside the cartridge.
System error: #02-000.
Please turn off then on
1. At warm up, the temperature is less
than reference temperature for 20
sec.
2. Abnormal ADC has occurred.
3. ZeroCross Signal detect error has
occurred.
1. In case of meaning 1, replace the
Fuser unit.
2. In case of meaning 3, replace the
Engine contol board or Fuser control
board or SMPS.
System error: #02-003.
Please turn off then on
The communication error of the
MEGA88 Micom
1. Open the side cover and close it.
2. Check the envelope pressing
device.
System error: #10-004.
Please turn off then on
UI error 1. check the UI connector.
2. If the problem persists, replace the
OPE board.
3. If ther problem persists, replace the
maina board.
This IP address
conicts with an IP
address already in use.
Check it
The IP address is used in other place
elsewhere.
Check the IP address or obtain a new
IP address.
Toner cartridge is not
compatible. Check
user's guide
The toner cartridge you have installed
is not for your machine.
Replace the toner cartridge.
Toner cartridge is not
installed. Install it.
The toner cartridge is not installed
or the CRUM in the cartridege is not
properly connected.
Check the connection between the
CRUM connector of the toner cartridge
and Set.
Toner cartridge is worn.
Replace with new one
The color toner cartridge has run out.
The machine stops printing.
Replace the toner cartridge.
Toner is empty. Replace
toner cartridge
The lifespan of the color toner
cartridge which the arrow indicates is
reached.
Replace the toner cartridge.
Toner is low. Order new
toner cartridge
Toner Cartridge is almost empty. Replace the toner cartridge.
Too much paper in
output bin tray. Remove
printed paper
The printed papers are full on the
output tray.
1. Remove the paper on outbin tray.
2. Check the Outbin Full Senosr
(Component Test -> Sensor Read ->
OB value)