4.Servi
c
Code Displayed Name
116-5680 Fnsh Low staple 2 sensor
C
116-5690 Fnsh Stopper home sensor
C
116-5700 Fnsh Front tamper home sensor
C
116
5710
Fnsh
Rear tamper home sensor
C
116
-
5710
Fnsh
Rear
tamper
home
sensor
C
122-0010 Duplex fan1 run
S
122-0100 Fuser out fan run
S
122-0110 SMPS In fan run
S
122-0120 SMPS out fan run
S
122-0140 Ozone suction fan run
S
122-0160 OPC In fan run
S
122-5000 Dupelx fan1 run ready
D
122-5090 Fuser out fan run ready
D
122-5100 SMPS In fan run ready
D
122-5110 SMPS out fan run ready
D
122-5130 Ozone suction fan run ready
D
s
122-5150 OPC In fan run ready
D
123-0010 Fuser center temperature
D
123-0020 Fuser side temperature
D
123
-
0040
Inner temperature
D
123
0040
Inner
temperature
D
123-0050 Inner humidity
D
123-0060 Outter temperature
D
123-0070 Outter humidity
D
T
abl
e
Service Manual
SCX-8030/8040 series
4-
2
c
e Mode
Meaning
C
heck Low staple 2
C
heck Stopper home
C
heck Front tamper home
Check Rear tamper home
Check
Rear
tamper
home
S
tart/Stop duplex fan1 run
S
tart/Stop fuser out fan
S
tart/Stop SMPS in fan
S
tart/Stop SMPS out fan
S
tart/Sto
p
ozone suction fan
p
S
tart/Stop OPC in fan
D
etects if duplex fan1 runs at normal speed
D
etects if fuser-out fan runs at normal speed
D
etects if SMPS-in fan runs at normal speed
D
etects if SMPS-out fan runs at normal speed
D
etects if ozone suction fan motor runs at normal
s
peed
D
etects if OPC-in fan motor runs at normal speed
D
isplay fuser center temperature
D
isplay fuser side temperature
Display temperature in Machine
Display
temperature
in
Machine
D
isplay humidity in Machine
D
isplay outter temperature
D
isplay outter humidity