4.6.10. TR Control Mode
• Service Functions > TR Control Mode
Purpose To correct transfer related probl
Operation
Procedure
1. TR Control Mode
• Choose the paper group, p
OPC Cyclic Ghost :
Blur
2. Blur Upgrade Mode : Turn on
3. OHP Upgrade Mode : Turn o
Note that this option needs to b
OHP printing. Most of OHP type
Verification Print out a test job and make su
Reference N/A
Service Manual
SCX-8030/8040 series
4-
ms. This function can be used to change the
per side, and paper direction.
se PWM value
Decrease PWM value
Poor Transfer
Retransfer
the mode when black lines becomes blur.
the mode when transfer on OHP becomes poor.
turned on only if there is a transfer problem in
s can be used without this option turned on.
e the transfer problem has resolved.
SAMSUNG ELECTRONICS
Version 0.05